What changed in version 0.2#
Version 0.1 defined an experiment that was procedurally rigorous but had no quantitative pass criteria — its gates were readiness gates, so the campaign could be executed perfectly and still not state whether anything had succeeded. Version 0.2 adds:
Addition Section Numeric acceptance thresholds traced to requirement IDs §11 Sample-size statistics — why 25 checkpoints beat 12 §8.1 A fourth processing path, P for photogrammetry §2 Three-tier metrology, so iteration is affordable §7.8 Synchronisation threshold of 1 ms, derived not assumed §6 Stage 3 Calibration verification at operating range §6 Stage 2 Pitch and azimuth tested for bias, not noise §9.1 Mechanically enforced checkpoint isolation §7.7 The procedural discipline of version 0.1 is unchanged and remains the strongest part of this document.
1. Purpose#
V1-00 defines a controlled, repeatable and independently referenced test campaign for Prototype V1.
The programme will assess whether one commercially available 3D LiDAR and one commercially available stereo/depth camera can be acquired, calibrated, synchronized and used jointly to produce spatial measurements relevant to rooftop solar surveying.
V1-00 is the experiment definition and measurement protocol. It does not select a sensor model, approve procurement, freeze a software stack or establish that any performance target has been achieved.
The campaign has two environments:
- V1-00A — Controlled indoor test: a repeatable test volume with known geometry and a roof-like mock structure.
- V1-00B — Rooftop field test: an accessible real roof, surveyed independently and tested under representative outdoor conditions.
Use the same temporary rigid sensor rig, data schema, measurement definitions and processing rules in both environments wherever practical.
2. Questions the experiment must answer#
- Can each sensor acquire and record usable data independently?
- Can camera intrinsics and LiDAR-to-camera extrinsics be calibrated repeatably?
- Can the data streams be placed on a common time base, and can residual timing offset/drift be measured?
- What geometry and visual information does each sensor contribute independently?
- Does joint LiDAR/stereo processing improve useful coverage or rooftop interpretation without degrading geometric accuracy?
- How repeatable are the measurements when the same scene and scan path are repeated?
- What failure modes appear on real roof materials, in sunlight/shade, around obstacles and during operator movement?
- What host-compute, bandwidth, storage, power and thermal constraints appear during sustained acquisition?
The main comparison is between four processing outputs produced from the same synchronized recording:
- L — LiDAR-only: LiDAR data and the LiDAR's supported motion information.
- S — Stereo-only: stereo/RGB/depth data and the camera's supported motion information.
- F — Fused: the selected combination of LiDAR and stereo data.
- P — Photogrammetric: structure-from-motion and multi-view stereo over the camera's motion baseline, rather than the fixed stereo baseline. (Added in 0.2.)
Do not compare separate scans captured at different times as though they were identical observations. Where simultaneous acquisition is possible, derive all paths from the same recording. Record any unavoidable difference in capture conditions.
2.1 What the error budget already settles — and how that sharpens the experiment#
The error budget answers some of these questions analytically. Those answers should be verified, not re-litigated, and the test effort redirected to what is genuinely unknown.
| Already settled analytically | Consequence for this campaign |
|---|---|
| Fixed-baseline stereo cannot range to ±20 mm beyond ~3 m (F-1) | Do not score path S on depth accuracy at 10 m. Test it for texture, edges, semantics, odometry contribution and short-range geometry. |
| A walking baseline supplies what the rig cannot (F-2) | Path P added — this is the open question stereo was wrongly expected to answer |
| Plane normals should reach ~0.03° from noise (F-6) | Test pitch and azimuth for systematic bias and repeatability, not noise |
| Sub-millisecond sync is required (F-8) | Stage 3 has a numeric threshold, not just a measurement instruction |
| Deskewing is mandatory (F-9) | Test it as a separate stage, with it on and off |
| Boresight residual is amplified by range (F-10) | Stage 2 verification observations at 8–15 m are mandatory |
Why this matters for cost. Question 5 in §2 — whether fused processing beats sensor-only processing — is partly answered before any purchase. Falcon does not need a field campaign to discover that a 50 mm stereo baseline will not range to 20 mm at 10 m. It needs a campaign to find out what stereo does contribute, whether photogrammetry over a walking baseline reaches useful accuracy, and whether the system's systematic errors can be controlled.
That is a sharper and cheaper experiment than an open-ended comparison.
3. Scope and non-goals#
In scope#
- Independent sensor acquisition and replay.
- Camera intrinsic calibration.
- LiDAR-to-camera extrinsic calibration.
- Coordinate-frame definition and transform verification.
- Timestamp semantics, clock offset, drift and synchronization tests.
- Static geometry, range, surface and repeatability tests.
- Controlled motion and scan-path tests.
- Rooftop geometry and environmental tests.
- Independent ground-truth survey and uncertainty reporting.
- Sensor-only versus fused-output comparisons.
- Data integrity, host load, bandwidth, storage, power and thermal logging.
Explicitly out of scope for V1-00#
- Final handheld enclosure, industrial design or production electronics.
- Custom LiDAR/camera/IMU development.
- Final vendor or sensor selection.
- Product certification or claims of standards compliance.
- Final acceptance of the provisional ±2 cm target.
- Production tooling or manufacturing release.
- Solar-panel layout automation as a V1-00 pass criterion.
4. Test configuration#
4.1 Prototype rig#
The initial test rig shall contain: - One developer-accessible 3D LiDAR. - One developer-accessible stereo/depth camera. - A rigid temporary mounting plate/frame with documented sensor positions and orientations. - A host computer capable of recording both sensor streams without avoidable data loss. - Required power supplies, cabling, storage and interface adapters. - Calibration targets visible to the relevant sensors. - A survey reference system and surveyed targets, as defined in Section 7.
An IMU may be internal to either device or external to the rig. Record exactly which IMU data is used by each processing path. Do not silently mix vendor-generated trajectory/SLAM output with raw sensor measurements.
GNSS is optional for V1-00 and is not the primary ground-truth source for local roof geometry.
4.2 Mechanical arrangement#
- Mount the LiDAR and stereo camera rigidly. Do not hand-hold individual sensors separately during comparative baseline acquisition.
- Record sensor origins, axes, mounting offsets, orientation and any relevant optical/sensor reference points.
- Mark the rig configuration with a revision identifier and photographs.
- Apply witness marks or another method to detect movement of a sensor after calibration.
- Do not change mounting geometry between comparative runs unless the change is recorded as a new rig revision.
- Measure and record any mechanical movement after transport, impact, re-tightening or remounting.
4.3 Coordinate frames#
Define and record at minimum:
- L: LiDAR sensor frame.
- C: Camera optical frame, using the manufacturer's documented axis convention.
- I: IMU frame, if available.
- R: Rigid rig frame.
- W: Local survey/world frame established by the reference control network.
Record the axis direction, handedness, origin and units for every frame. Store every calibration transform with an explicit source frame, destination frame, units, convention and version. Do not rely on a transform filename alone to communicate its meaning.
5. Test environments and scenarios#
5.1 V1-00A — Controlled indoor test#
Use an indoor area that can provide repeatable target placement and, where possible, clear lines of sight at approximately 2 m, 5 m and 10 m. Add a longer range only if the facility safely permits it.
The scene should include: - A flat vertical plane and a flat horizontal plane. - A rigid mock-roof arrangement with at least two inclined planes. - A visible roof edge, corner or ridge. - At least one obstacle or occluding object. - Textured and low-texture surfaces. - Light, dark and moderately reflective surfaces where safe and practical. - Surveyed control targets and independent check targets distributed through the test volume.
For the mock roof, nominal panel inclinations of 0°, 15° and 30° may be used as convenient setup values. The surveyed angles and coordinates—not the nominal settings—are the reference truth. If the site or fixture cannot provide these exact angles, record the actual geometry instead of forcing it.
| ID | Scene | Primary purpose |
|---|---|---|
| IN-01 | Static planes and surveyed targets | Baseline range, geometry, noise and repeatability |
| IN-02 | Mock-roof panels at measured inclinations | Plane fit, pitch, orientation and dimension checks |
| IN-03 | Textured and low-texture surfaces | Stereo depth robustness and failure characterization |
| IN-04 | Obstacles and partial occlusion | Coverage, edge/obstacle representation and missing data |
| IN-05 | Controlled rig movement along a marked path | Timing, motion distortion, registration and trajectory stability |
5.2 V1-00B — Real rooftop test#
Use the available rooftop site only after access permission, safe access and the reference survey plan have been confirmed.
The roof should, where available, include: - At least two distinct roof planes or slope conditions. - A measurable roof boundary, edge, ridge or parapet. - One or more fixed obstacles such as a tank, duct, skylight or other roof feature. - More than one surface/material or texture condition, if available. - Areas exposed to direct sunlight and shade during the test window. - Sufficient clear space to perform a repeatable scan path without approaching unsafe edges.
If the selected roof lacks one of these features, record the limitation and supplement it with a safe, controlled target or mock feature. Do not infer performance on a surface that was not actually tested.
| ID | Scene | Primary purpose |
|---|---|---|
| RF-01 | Static scan of a surveyed roof area | Absolute/local geometry and completeness |
| RF-02 | Repeated scan of the same area | Repeatability and operator sensitivity |
| RF-03 | Controlled walking path with turns | Motion, synchronization and SLAM/registration behaviour |
| RF-04 | Sunlit versus shaded surfaces | Optical and depth robustness |
| RF-05 | Roof edges, parapets and obstacles | Boundary and obstacle representation |
Record roof material, approximate surface condition, weather, temperature, time, direct sun/shade, wind, and any wet or unsafe condition. Do not scan in rain or on wet/unsafe roof surfaces during this initial protocol.
6. Test sequence#
Execute the sequence in order. Do not proceed to a later stage if an earlier stage has an unresolved failure that invalidates its data.
Stage 0 — Readiness and safety#
- Confirm exact sensor model, SKU, serial number and hardware revision.
- Record firmware, SDK, driver, middleware and host OS versions.
- Verify storage capacity, sustained write speed, network/interface setup and power.
- Confirm the sensor rig is mechanically stable.
- Review the survey control plan and reference-instrument verification.
- Confirm site access, safe work method, weather and rooftop safety arrangements.
- Freeze the test scene, target IDs, scan route, sensor settings and processing version for the run series.
Stage 1 — Independent static sensor baseline#
- Warm up devices according to their manufacturer instructions.
- Record LiDAR-only and camera/stereo-only data in the same static scene.
- Capture simultaneous data if both sensors can operate at once.
- Capture configuration, timestamps, device status and host metrics.
- Repeat the same scene without changing the target arrangement.
- Inspect data integrity before processing.
Stage 2 — Calibration#
- Calibrate camera intrinsics using a rigid, dimensionally characterized checkerboard or ChArUco target.
- Capture calibration observations at multiple positions, distances and orientations across the image field.
- Keep a separate set of target poses for calibration verification.
- Calibrate LiDAR-to-camera extrinsics using a target or target arrangement visible to both modalities.
- Use multiple non-parallel target orientations and adequate range variation; avoid solving extrinsics from one plane/view only.
- Record calibration residuals, method, software version, data used and estimated uncertainty.
- Remove and remount the sensor only as a deliberate repeatability test; recalibrate and compare the resulting transform.
- Report the boresight (angular) and lever-arm (translational) residuals separately. They behave differently with range and must not be combined into a single figure.
- Capture verification observations at 8–15 m, not only at calibration-target distance. (Added in 0.2.)
Why step 9 is mandatory. Angular extrinsic error is amplified linearly by range, while translational error is not. A calibration performed at a comfortable 2 m with a typical 0.2° residual contributes only 7 mm at that distance but 35 mm at 10 m and 52 mm at 15 m — on its own exceeding the target tolerance.
Calibrating at 2 m and operating at 15 m amplifies angular residual 7.5×. A calibration that looks excellent on the target can therefore fail silently in use, and the resulting error will look like sensor inaccuracy.
Acceptance target: boresight residual ≤0.05°, verified at operating range (FR-08).
Calibration data must be labelled and stored separately from independent accuracy checkpoints.
Stage 3 — Synchronization#
- Identify each device's clock source, timestamp origin, time unit, rollover behaviour and whether timestamps are acquisition-time or host-arrival-time.
- Record available hardware triggering, PTP, sync-in/sync-out and software synchronization options.
- Measure clock offset and drift using the best common event or hardware timing method available for the selected devices.
- If only software timestamps are available, record host arrival time separately from sensor time; do not treat them as equivalent.
- Perform a controlled motion observation so that timing error can also be examined as geometric misalignment.
- Report measured synchronization performance and limitations. A vendor claim such as “microsecond-level synchronization” is not a Falcon measurement.
- Test deskewing as a separable stage — process the same recording with per-point motion compensation enabled and disabled, and quantify the difference. (Added in 0.2.)
Synchronisation threshold — derived, not assumed (added in 0.2)#
Timing error becomes geometric error through rotation:
error = R · ω · Δt. At a natural handheld panning rate of 30 °/s, the offset that keeps timing-induced error at or below 5 mm at 10 m range is:
Angular rate Maximum permissible offset 15 °/s 1.9 ms 30 °/s 0.95 ms 90 °/s (during turns) 0.32 ms Acceptance threshold: measured inter-sensor offset better than 1 ms, with drift characterised over the capture interval (DR-02).
A system that can only achieve software timestamping, with jitter typically exceeding 10 ms, is usable for early algorithm work but is disqualified for the product. Record that distinction explicitly rather than reporting the offset as a neutral observation.
Expected magnitude of the deskewing test in step 7. Within one 100 ms frame of a 10 Hz LiDAR, panning at 30 °/s sweeps 3°, which at 10 m is about 524 mm of apparent smear. If the measured difference between deskewed and non-deskewed output is far smaller than this, the deskewing implementation is probably not working — treat an unexpectedly small difference as a defect to investigate, not as good news.
Stage 4 — Static geometry and range#
- Scan the surveyed indoor scene from a fixed rig position.
- Repeat at each usable range band.
- Process L, S and F outputs from the same recorded data where available.
- Compare surveyed checkpoint coordinates, reference distances, plane geometry and surface coverage.
- Record surface-specific failures and outliers rather than deleting them without explanation.
Stage 5 — Controlled movement#
- Mark a repeatable route with a straight segment, at least one turn and a return/loop segment where the site permits.
- Record route geometry and approximate traversal time.
- Keep the rig mounting and sensor settings unchanged.
- Perform repeated traversals at a measured, controlled pace; record actual time and route deviations.
- Evaluate map closure, trajectory drift, timing-related distortion and reconstruction repeatability.
Stage 6 — Rooftop validation#
- Complete the reference survey before scanning.
- Photograph and record the test layout, target IDs, material and environment.
- Acquire a static scan and a controlled walking scan.
- Repeat the scan path.
- Capture sunlit and shaded conditions where practicable.
- Process L, S and F using the same locked processing configuration.
- Compare results with independent surveyed checkpoints and roof geometry.
Stage 7 — Review and freeze results#
- Verify data completeness and checksums.
- Confirm that no independent checkpoint was used for calibration, tuning or registration.
- Run the agreed metric scripts with locked versions and parameters.
- Produce sensor-specific and fused results.
- Record deviations, failed runs and exclusions with reasons.
- Publish the experiment report and decide the next engineering action.
7. Ground-truth and reference-measurement protocol#
7.1 Principle#
The reference measurements must be independent of the candidate LiDAR/stereo system. The candidate device must not be used to establish the truth against which it is evaluated.
For V1-00, the preferred reference is a survey-grade total station operated by a competent surveyor, with a documented and redundantly observed local control network. A calibrated terrestrial laser scanner may be used as a secondary comparator, but it is not automatically ground truth merely because it is a commercial scanner.
A calibrated steel tape or suitable calibrated distance meter may be used as a secondary check for selected linear dimensions. It is not sufficient by itself to establish a 3D coordinate network or roof-plane truth.
Do not use phone GPS, a consumer phone LiDAR scan, an unverified BIM/CAD drawing or the candidate scanner's own map as the primary ground truth.
7.2 Reference instrument readiness#
Before surveying: - Record the total-station manufacturer, exact model, serial number, angular accuracy, EDM accuracy, prism/reflector configuration, firmware and last calibration/verification date. - Record the surveyor/operator and field procedure. - Perform instrument setup checks and field verification appropriate to the equipment. - Record target centring method, prism constant, pole/tribrach setup and any offsets between the measured prism point and the physical target centre. - Where the total station is rented or supplied by a survey contractor, obtain the instrument specification and calibration/verification record. - Do not infer reference uncertainty from the instrument brochure alone; include network geometry, setup, centring, target definition and repeat-observation effects.
7.3 Local reference network#
- Establish a local right-handed coordinate system with documented origin, axes and units.
- Place at least six stable survey control targets around and through the test volume. Distribute them in depth and height; avoid a purely straight-line or single-plane arrangement.
- Observe the network from more than one instrument setup where practical.
- Include redundant observations and a closed traverse or equivalent network closure check.
- Re-observe selected control points independently.
- Adjust the reference network and retain raw observations, adjustment report, residuals, closure and estimated coordinate uncertainty.
- Recheck at least two stable reference marks at the end of each test session to identify movement or survey drift.
If the network closure, target stability or reference uncertainty is inadequate, the affected scan series is not suitable for absolute-accuracy claims.
7.4 Control targets versus independent checkpoints#
Separate reference points into two groups before scanning:
A. Registration/control targets - Use at least six well-distributed targets to establish the transformation from the scan's local frame to the surveyed world frame, where such a transformation is required. - The same defined control set and registration method must be used for all comparable outputs. - A single rigid six-degree-of-freedom transform may be estimated from these control points. Do not apply a scale change.
B. Independent check points - Use at least twelve independently surveyed checkpoints distributed across the test volume and relevant surfaces for an initial V1 engineering trial. Version 0.2 recommends 25 — see §8.1 for why twelve is statistically marginal and why the upgrade is cheap once a surveyor is mobilised. - Include points at different ranges, heights, planes, roof edges and obstacle locations where possible. - The check points must not be used to estimate the transform, calibrate sensors, tune SLAM, tune parameters, remove outliers or select the best scan. - If fewer than twelve independent checkpoints are available, report the actual sample size and treat the result as a limited pilot rather than a broad accuracy validation.
Each target must have a well-defined physical centre or measurement feature. If the total station prism centre differs from the centre identified by LiDAR/camera, measure and document that offset. A target's centre definition must not be guessed from the image or point cloud.
7.5 Reference geometry and dimensions#
For each test scene, survey and record: - Checkpoint coordinates and target IDs. - At least three independent reference distances spanning the available range, with endpoints defined physically. - Mock-roof panel corner coordinates and dimensions. - Roof-plane points sufficient to fit each reference plane. - Key roof edge, ridge, parapet and obstacle points. - Target centre offsets and dimensions. - Any reference measurements taken by calibrated tape/distance meter as cross-checks.
For a plane, survey multiple non-collinear points distributed over the surface. Derive the reference plane and its normal from the surveyed coordinates. Do not use the mock panel's nominal angle as truth.
For an edge or corner, define the exact physical feature being measured. Record whether the comparison is to a sharp edge, target centre, fitted intersection of planes or another explicit geometric definition.
7.6 Reference uncertainty and the provisional ±2 cm target#
The early ±2 cm figure is a provisional project target, not an approved acceptance requirement.
As an internal V1 metrology rule, the expanded uncertainty of the reference measurement should be no more than one-third of the tolerance being evaluated. This is an experiment-design rule for Falcon, not a quoted ISO requirement.
If ±20 mm is used as a trial tolerance, aim for reference expanded uncertainty U95 of approximately 6 mm or better for the relevant measurand. If this cannot be demonstrated, do not claim that the test proves or disproves ±20 mm performance. Report the observed differences, the reference uncertainty and the limitation; use the data for comparative geometry and repeatability only.
Prepare an uncertainty budget that considers: - Instrument calibration/specification and field verification. - Angular and distance observation uncertainty. - Target centring and target-centre definition. - Network adjustment and closure. - Instrument setup, levelling and resection. - Atmospheric and environmental effects where relevant. - Repeatability of reference observations. - Any transformation between target/prism centre and the feature seen by the candidate sensors.
Report standard uncertainty components, combined uncertainty and expanded uncertainty with the coverage factor/assumption stated. Follow the principles of the Guide to the Expression of Uncertainty in Measurement rather than reporting only the nominal total-station specification.
7.7 Preventing ground-truth leakage#
This is mandatory.
- Do not use independent check points in camera intrinsic calibration.
- Do not use independent check points in LiDAR-camera extrinsic calibration.
- Do not use independent check points to initialize or refine the scan-to-world transform.
- Do not use ICP or full-cloud best-fit alignment against the reference scan to produce the primary absolute-accuracy result.
- Do not tune processing parameters after viewing checkpoint errors and then report the same points as independent validation.
- Do not remove difficult points/surfaces simply because they worsen the score. Use documented pre-defined quality rules and report exclusions.
- If an ICP/best-fit alignment is used for diagnostic shape-only comparison, report it separately and label it shape after best-fit alignment, never as absolute accuracy.
The primary coordinate-error result must use the control-point transformation only and then evaluate the untouched check points.
Enforce this in software, not only by discipline. (Added in 0.2.) These rules are correct but rely on sustained human care across a long campaign under time pressure — exactly the conditions in which such rules fail. The evaluation harness requirement SW-06 makes leakage mechanically impossible: control points are supplied to the pipeline, checkpoints exist only in the evaluator, and the pipeline cannot read the checkpoint store.
Build that isolation before the first formal run. It converts a procedural rule into a structural guarantee, and it is the single highest-value piece of software in the campaign.
7.8 Three-tier metrology — so that iteration is affordable (added in 0.2)#
Version 0.1 required survey-grade reference for all work. That is correct for accuracy claims and too expensive for daily iteration, and a protocol that is too expensive to run gets bypassed.
| Tier | Reference method | Typical U95 | Use for | May support an accuracy claim? |
|---|---|---|---|---|
| M1 — Workshop | Calibrated scale bars, a dimensionally characterised artefact, calibrated distance meter | 2–5 mm over short baselines | Daily iteration, regression checks, debugging, sanity checks | No |
| M2 — Local network | Total station, single setup, limited redundancy | ~5–10 mm | Repeatability, comparative L/S/F/P work, pre-field rehearsal | Comparative only |
| M3 — Full survey | Redundant adjusted network, closure checks, full uncertainty budget per §7.3 and §7.6 | ≤6 mm for a 20 mm tolerance | All formal absolute-accuracy results | Yes |
Rules:
- Only M3 supports an absolute-accuracy claim. M1 and M2 results must be labelled with their tier and must never be quoted as validation.
- Every result records its metrology tier. A result without a tier is not a result.
- M1 is strongly encouraged for routine work. A calibrated scale bar in the test volume catches gross scale and registration errors immediately, costs almost nothing, and would detect the most embarrassing class of failure before a surveyor is ever mobilised.
- Build the M1 artefact first. It is also the fastest way to validate the evaluation harness itself.
A scale bar is the cheapest insurance in this programme. A systematic scale error — from a mis-specified unit, a wrong focal length or an inverted transform — is both the easiest error to make and the easiest to catch, provided something of known length is in every scan.
8. Repeatability and sample plan#
For the initial V1 engineering campaign:
- Perform at least three debug runs to stabilize the setup and identify recording/calibration problems.
- After the setup is frozen, acquire at least five formal repeat runs for each key scenario.
- Use the same marked route, target arrangement, sensor settings and processing version across repeats.
- Where LiDAR and stereo can be recorded together, process L, S and F from the same recording.
- Record every failed run. A failed run may be excluded from a metric only with a written reason; it remains part of the data-integrity record.
- Randomize or rotate scenario order where practical so that time-of-day, lighting, warm-up or operator fatigue do not systematically favour one configuration.
Five repeats are an engineering screening sample, not a statistical certification sample. Increase the sample count if variability is high or if a later product requirement demands a confidence claim.
8.1 Sample size — what the specified counts actually buy (added in 0.2)#
Version 0.1 set minimum counts without stating what confidence they support. They turn out to be marginal, and the fix is cheap.
The relative standard error of an RMSE estimate is approximately 1/√(2n):
| Checkpoints | Standard error of RMSE | 1σ band on an observed 20 mm RMSE | Observed RMSE needed to claim ≤20 mm with a 2 SE margin |
|---|---|---|---|
| 6 | 28.9 % | ±5.8 mm | 12.7 mm |
| 12 (current minimum) | 20.4 % | ±4.1 mm | 14.2 mm |
| 20 | 15.8 % | ±3.2 mm | 15.2 mm |
| 25 (recommended) | 14.1 % | ±2.8 mm | 15.6 mm |
| 50 | 10.0 % | ±2.0 mm | 16.7 mm |
Three rules follow:
- At 12 checkpoints, an observed RMSE of 20 mm and one of 25 mm are statistically indistinguishable. The uncertainty on the estimate is ±4 mm at one sigma.
- To claim conformance with a 20 mm tolerance at 12 checkpoints, the observed RMSE must be ≤14.2 mm — not 20 mm. Reporting an observed 19 mm as "meets ±20 mm" is unsupportable.
- Raise the minimum to 25 independent checkpoints. The marginal cost of 13 more surveyed points during a mobilisation already underway is small; the gain in defensibility is large.
- Percentile estimates shall be flagged as unstable where
n < 20. With n = 12 the maximum observation is not a stable 95th-percentile estimate, and must not be presented as one. - Every reported metric shall carry
nand its standard error. A metric without a sample size is not reportable.
This matters commercially, not just statistically. If a V1 result is ever shown to an EPC customer or a prospective investor, the first competent question will be about sample size. Reporting "3D RMSE 16 mm, n = 25, SE 2.3 mm, reference U95 4.2 mm" is defensible. Reporting "±2 cm achieved" is not, and is hard to walk back.
9. Metrics and reporting definitions#
Report the metric, sample count, reference uncertainty, processing configuration and exclusions together. Do not report a single headline accuracy number without its measurement definition.
| Metric | Definition / reporting method | Interpretation |
|---|---|---|
| Signed distance error | Reconstructed distance minus surveyed reference distance | Reveals bias and error by range |
| Absolute distance error | Absolute value of signed distance error | Simple dimensional error |
| Checkpoint coordinate error | Difference between reconstructed and surveyed X, Y and Z coordinates | Separates horizontal and vertical behaviour |
| 3D checkpoint error | Euclidean norm of the X/Y/Z coordinate difference | Overall point-coordinate discrepancy |
| Bias | Mean signed error per axis or measurand | Detects systematic offset |
| RMSE | Square root of mean squared error for the stated measurand | Combines bias and scatter; always name the measurand |
| Plane-fit residual | Orthogonal residuals of reconstructed points to a fitted plane | Describes local surface noise/flatness; not by itself absolute accuracy |
| Plane-normal error | Angle between reconstructed and surveyed reference-plane normals | Roof-pitch/orientation geometry |
| Plane-offset error | Signed perpendicular offset between reconstructed and surveyed planes after control-only registration | Absolute plane placement |
| Edge/feature error | Difference in explicitly defined surveyed edge/corner/obstacle location | Roof-boundary and obstacle suitability |
| Repeatability | Spread of the same metric across repeated runs | Stability of the result |
| Coverage/completeness | Fraction of pre-defined reference surface cells/regions with valid reconstructed support | Missing-data behaviour; grid size and valid-support rule must be fixed before comparison |
| Trajectory/loop closure | Difference between estimated return pose/location and independent reference | Motion and mapping drift |
| Synchronization offset/drift | Difference between sensor time bases over the capture interval | Timing consistency |
| Data integrity | Frame/packet drops, recording gaps, corrupt files and timestamp discontinuities | Acquisition reliability |
| Resource load | CPU/GPU, memory, bandwidth, storage rate, power and temperature | Host/platform feasibility |
For coordinate results, report at minimum: - Mean signed error by axis. - RMSE by axis. - 3D checkpoint RMSE. - Median and maximum observed 3D error. - Number of independent checkpoints. - Reference expanded uncertainty.
For low sample counts, do not imply that a calculated 95th percentile is a stable population estimate. Report sample count and observed range clearly.
For completeness, define the region of interest, grid/cell size and minimum valid point/depth support before comparing L, S, F and P. A default 100 mm grid may be used for early visual screening, but it is a study parameter, not a final product requirement.
The 100 mm grid choice is quantitatively sound. At 10 m a 0.7° channel spacing gives 122 mm point spacing, so a 100 mm cell is well matched to the native sampling. Retain it, and record the point spacing alongside it so the comparison is interpretable at other ranges.
9.1 Measurand-specific reporting (added in 0.2)#
A single headline accuracy number is not reportable. Error behaves differently per measurand, and each requires a different statistic and a different test design.
| Measurand | Requirement | Report | Note |
|---|---|---|---|
| 3D checkpoint coordinate | MR-11 | RMSE by axis, 3D RMSE, median, max, n, SE | Control-only registration |
| Local distance | MR-12 | Signed and absolute error against baseline length | Fit to the ±(a + b·L) form, do not quote one number |
| Plane normal — pitch, azimuth | MR-03, MR-04 | Mean signed error (bias) and repeatability | See below |
| Plane offset | MR-05 | Signed offset after control-only registration | — |
| Roof boundary | MR-01 | Error against boundary length | Must be plane-intersection derived (FR-07) |
| Roof area | MR-02 | Percentage error | — |
| Obstacle height, parapet | MR-06, MR-08 | 95th percentile and max | — |
| Obstacle detectability | FR-03 | Detection rate by object size and range | Sampling-limited, not precision-limited |
| Coverage | FR-04 | Fraction of cells with valid support | Grid fixed before comparison |
Pitch and azimuth must be tested for bias, not noise. The error budget Finding F-6 shows that a 3 m patch with a thousand points should give plane-normal uncertainty of roughly 0.03° from random noise — more than ten times inside the ±0.5° requirement.
Reporting that random noise is small would therefore be a meaningless result: it is predicted, and it is not where the risk lies. The real risks for angular measurands are systematic: calibration bias, pose tilt error, incidence-angle-dependent bias, and gravity-vector error from IMU misalignment.
Test design follows from this. Measure the same surveyed plane from multiple device orientations and standoff distances, and look for a consistent offset rather than scatter. If the measured scatter is close to 0.03° but a 0.3° bias appears consistently, the device has a systematic problem that a noise-focused test would have reported as excellent performance.
10. Comparative analysis rules#
- Process L, S and F from the same source recording wherever possible.
- Keep the raw input unchanged and record a checksum.
- Use the same surveyed control targets for the primary control-only frame transform.
- Keep all independent checkpoints hidden from calibration, alignment and tuning.
- Keep the software version, configuration and parameter set fixed for the formal run series.
- Report both absolute/control-aligned results and diagnostic shape-only/best-fit results separately.
- Compare the fused output against each sensor-only result using pre-defined metrics.
- A fused result is beneficial only if it delivers a measurable improvement in a product-relevant dimension—such as coverage, edge definition, surface completeness or robustness—without unacceptable degradation in geometry, repeatability or acquisition reliability.
- If the fused output is no better, document that honestly. V1 is allowed to conclude that one sensor is unnecessary for a particular task.
Do not choose the “best-looking” point cloud as the winner. Use the locked metrics and ground-truth checkpoints.
11. Preliminary trial acceptance gates#
These are readiness and engineering gates, not final product requirements.
Version 0.2 adds numeric thresholds. Version 0.1's gates were checklists of things to have done, which meant the campaign could be executed perfectly and still not state whether anything had succeeded. Each gate now has a measurable criterion with a pass, conditional and fail verdict, traced to a requirement ID.
11.0 Quantitative gate criteria (added in 0.2)#
| Gate | Criterion | Pass | Conditional | Fail | Trace |
|---|---|---|---|---|---|
| A | Reference expanded uncertainty, U95 | ≤6 mm | 6–10 mm | >10 mm | §7.6 |
| A | Network closure and residuals | within adjustment tolerance | — | outside | §7.3 |
| A | Independent checkpoints available | ≥25 | 12–24 | <12 | §8.1 |
| B | Recording loss, unexplained | 0 | <0.1 % explained | any unexplained | §6 St.1 |
| B | Replay determinism | bit-identical decode | — | differs | SW-04 |
| C | Inter-sensor sync offset | ≤1 ms | 1–10 ms | >10 ms, or software-only | DR-02 |
| C | Sync drift over capture interval | characterised and bounded | — | uncharacterised | §6 St.3 |
| C | Boresight residual | ≤0.05° | 0.05–0.2° | >0.2° | FR-08 |
| C | Boresight verified at 8–15 m | yes | — | no | §6 St.2 |
| C | Remount transform repeatability | ≤0.1° and ≤2 mm | — | worse | §6 St.2 |
| D | Plane normal bias, pitch | ≤0.2° | 0.2–0.5° | >0.5° | MR-03 |
| D | Plane normal repeatability | ≤0.1° | — | >0.3° | MR-03 |
| D | Local distance error, L ≤ 10 m | ≤(10 mm + 1 mm/m) | within 2× | worse | MR-12 |
| D | Plane offset | ≤25 mm | 25–50 mm | >50 mm | MR-05 |
| D | Roof area error | ≤2 % | 2–5 % | >5 % | MR-02 |
| D | Coverage on defined ROI | ≥95 % | 85–95 % | <85 % | FR-04 |
| E | Obstacle detection, ≥150 mm objects | ≥95 % | 85–95 % | <85 % | FR-03 |
| E | Obstacle height error, 95th pct | ≤50 mm | 50–100 mm | >100 mm | MR-06 |
| E | Parapet height error | ≤25 mm | 25–50 mm | >50 mm | MR-08 |
Verdict rules
- A Conditional result is not a failure. It is a quantified limitation that must be carried into the report and into the product requirements, and must not be rounded up to a pass.
- Any Fail on Gate A restricts accuracy claims for every dependent result, per §7.6. This cascade is deliberate.
- A software-only synchronisation result fails Gate C for the product even if the data is usable for algorithm work. Record both verdicts separately.
- Gates D and E are evaluated per processing path — L, S, F and P — and a path may pass some criteria and fail others. That pattern is the useful output: it shows what each sensor actually contributes.
- No gate may be passed on a sample that violates §7.7 leakage rules, regardless of how good the numbers look.
The expected outcome is a mixed verdict, and that is a success. A campaign returning all passes on first attempt would more likely indicate a measurement or leakage problem than an exceptional device. Mixed results traced to specific causes are what redirect engineering effort — which is the purpose of V1-00.
Gate A — Metrology ready#
- Reference instrument details and verification record captured.
- Control network adjusted with acceptable closure/residuals.
- Independent check points physically separate from control points.
- Reference uncertainty estimated and documented.
- If the uncertainty is too high for the tolerance under evaluation, accuracy claims are explicitly restricted.
Gate B — Acquisition ready#
- Both sensor streams recorded without unexplained gaps.
- Device/SDK/firmware/host configuration recorded.
- Raw data, timestamps and metadata preserved.
- Replays reproduce the same decoded measurements.
Gate C — Calibration and timing ready#
- Calibration datasets and independent verification datasets separated.
- Calibration residuals and transform uncertainty recorded.
- Timestamp semantics and measured offset/drift documented.
- Remounting or rig movement is detected and handled through a documented recalibration rule.
Gate D — Comparative experiment complete#
- L, S and F outputs generated from comparable recordings.
- Primary metrics computed against independent checkpoints.
- Coverage and failure modes documented.
- Repeat runs completed and variability reported.
- Processing configuration and raw-data checksums archived.
Gate E — Rooftop relevance assessed#
- Indoor and rooftop results compared.
- Sun/shade, surface and obstacle limitations recorded.
- Solar-survey relevance assessed with dimensions, planes, boundaries and obstacles.
- Next experiment and any hardware/software changes justified by evidence.
Passing these gates does not mean the final product meets ±2 cm or any other product accuracy requirement.
12. Data management and run record#
Each run shall receive a unique ID, for example:
- IN-01-LAB-YYYYMMDD-R01
- IN-05-MOTION-YYYYMMDD-R03
- RF-01-ROOF-YYYYMMDD-R01
The run folder should contain:
- metadata/ — run sheet, site notes, sensor configuration, calibration IDs and software versions.
- raw/ — original LiDAR, image, depth, IMU and sensor-native files.
- reference/ — total-station observations, adjusted coordinates, target register, closure report and uncertainty budget.
- calibration/ — intrinsics, extrinsics, target files and verification residuals.
- processed/ — derived point clouds, maps, meshes and trajectories.
- metrics/ — scripts, configuration, checkpoint residuals, charts and summaries.
- photos/ — rig, target layout, roof conditions and setup photographs.
- logs/ — device, driver, middleware, host and acquisition logs.
Never overwrite raw data. Store the file checksum and retain the processing code/configuration used to produce each result.
12.1 Run-sheet template#
| Field | Entry |
|---|---|
| Run ID | |
| Date / local time | |
| Environment / scenario ID | |
| Site / roof / indoor area | |
| Operator / surveyor | |
| Weather / temperature / sun-shade | |
| Roof/material/surface notes | |
| LiDAR model / SKU / serial / firmware | |
| Camera model / SKU / serial / firmware | |
| IMU source / firmware | |
| SDK / driver / ROS version | |
| Host OS / CPU / GPU / RAM | |
| Rig revision / mounting configuration | |
| Calibration IDs | |
| Control network ID / check-point set ID | |
| Sensor settings / frame rates / exposure | |
| Sync mode / clock source | |
| Scan path / duration / approximate speed | |
| Raw data files / checksums | |
| Processing version / parameters | |
| Failed frames / gaps / exclusions | |
| Safety or site deviations | |
| Observations / anomalies | |
| Reviewer / review date |
12.2 Checkpoint residual template#
| Check ID | Reference X | Reference Y | Reference Z | Scan X | Scan Y | Scan Z | ΔX | ΔY | ΔZ | 3D error | Used for control? |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CP-001 | No | ||||||||||
| CP-002 | No | ||||||||||
| CP-003 | No |
Keep control points in a separate table and label them explicitly as registration/control. Independent checkpoint rows must remain marked “No”.
13. Safety and site controls#
- Obtain property/site permission before installing targets or conducting scans.
- Use a site-specific rooftop safe-work procedure and competent supervision.
- Do not approach or scan from unprotected roof edges; do not sacrifice safe positioning to improve scan coverage.
- Stop work during rain, wet/unsafe roof conditions, lightning or other unsafe weather.
- Secure tripods, cables, batteries and temporary fixtures against trip hazards and movement.
- Follow each sensor's laser classification and manufacturer safety instructions. Never look into an emitting aperture or defeat protective measures.
- Do not attach targets to fragile roof materials or alter waterproofing without permission.
- Record any occlusion or inaccessible region caused by safe operating limits rather than attempting unsafe access.
14. Deliverables#
V1-00 is complete when the project has:
- Indoor site layout and target-location plan.
- Rooftop site layout and safe scan-route plan.
- Reference control-network report and adjusted coordinate file.
- Independent checkpoint register.
- Reference uncertainty budget.
- Rig configuration and calibration record.
- Sensor/host configuration and acquisition-readiness record.
- Indoor test dataset and run sheets.
- Rooftop test dataset and run sheets.
- Metric scripts/configuration and comparative results.
- Failure log and limitations.
- An engineering recommendation for the next V1 experiment.
15. Standards and technical references#
These references inform the measurement approach. V1-00 is an internal engineering protocol and must not be described as compliant with a standard unless the full standard's applicable procedures and requirements have been reviewed and followed.
- ISO 17123-9:2018 — Field procedures for testing terrestrial laser scanners. The published 2018 edition addresses field evaluation of scanner precision/repeatability and notes that the procedures are not comprehensive acceptance/performance tests. ISO lists a second edition, ISO/CD 17123-9, as under development; the committee draft was registered in August 2026 and is not a published replacement.
- ISO 17123-5:2018 — Field procedures for testing total stations. The published edition is confirmed as current and addresses field evaluation of total-station coordinate-measurement precision/repeatability.
- ISO/IEC Guide 98-3:2008 — Guide to the expression of uncertainty in measurement (GUM), together with Amendment 1:2026 on nonlinearity in measurement models, for the uncertainty-budget approach.
The standards guide the discipline of testing and reporting. The checkpoint layout, control/check split, repetition counts and one-third reference-uncertainty rule in this document are Falcon's proposed internal protocol, not requirements quoted from those standards.
16. V1-00 pre-execution checklist#
Do not begin formal scans until the following are filled and reviewed:
- [ ] Indoor room/test volume selected and measured.
- [ ] Rooftop site confirmed, permission and safety controls complete.
- [ ] Mock-roof fixture and target layout finalized.
- [ ] LiDAR and stereo/depth camera exact models and SDK versions identified.
- [ ] Rigid rig built, measured and photographed.
- [ ] Total station / surveyor arranged, instrument verification record obtained.
- [ ] Control targets and independent checkpoints labelled and placed.
- [ ] Reference network closed, adjusted and uncertainty assessed.
- [ ] Control/check separation documented and protected.
- [ ] Camera/LiDAR calibration targets and procedures prepared.
- [ ] Scan paths and run IDs prepared.
- [ ] Raw-data storage, checksum and backup process tested.
- [ ] Processing versions and parameter freeze procedure prepared.
- [ ] Rooftop safe-work review completed.
Added in version 0.2:
- [ ] Evaluation harness built and validated against a public dataset with known ground truth (software plan Phase S0).
- [ ] Checkpoint isolation enforced in software, not only by procedure (SW-06).
- [ ] M1 calibrated scale bar or dimensional artefact built and available in every scan (§7.8).
- [ ] Metrology tier recorded for every planned run.
- [ ] Photogrammetry path P processing route prepared (§2).
- [ ] Deskewing implemented as a separable, switchable stage (§6 Stage 3 step 7).
- [ ] Quantitative gate criteria in §11.0 reviewed and agreed before acquisition begins.
- [ ] Target of 25 independent checkpoints confirmed with the surveyor (§8.1).
Agree the gate criteria before acquiring data, not after. Thresholds set after seeing results are not thresholds. This is the same principle as §7.7's prohibition on tuning after viewing checkpoint errors, applied to the acceptance criteria themselves.
Decision at the end of V1-00: confirm whether the team has enough metrology, site and data-acquisition readiness to execute the formal V1 test campaign. If not, close the specific readiness gaps before sensor performance testing.
Source: docs/04-rd/V1-00_EXPERIMENT_SPECIFICATION.md