SUNRACK TECHNOLOGIES LLP · PROJECT FALCON

Error Budget and Feasibility Analysis

Analysis — derived from published specifications and first principles; contains no Falcon measurements

Document ID

FALCON-ERR-001

Version

0.1

Status

Analysis — derived from published specifications and first principles; contains no Falcon measurements


1. Why this document exists#

Every other Falcon document says the ±2 cm target is "provisional" and must be validated by test. None of them asks the prior question: is it physically achievable, and by which sensor, for which measurand, at which range?

That question can be answered analytically before any hardware is purchased. Doing so is cheaper than discovering the answer through a failed test campaign, and it tells the V1-00 campaign what to measure and what thresholds mean something.

This document builds an error budget from published sensor specifications and standard measurement physics. It then states which measurands are feasible, which are marginal and which are not achievable with the candidate architecture.

What this document is, and is not#

It is It is not
An analytical prediction with stated assumptions A measurement result
A tool for setting test thresholds and sensor requirements A vendor claim or an endorsement
Falsifiable — Section 12 states what would disprove it A substitute for the V1-00 campaign

Evidence labels follow the Procurement Matrix Guidance vocabulary. Vendor-published inputs are labelled (official specification). Everything derived here is labelled (Falcon analysis). No figure in this document is a Falcon measurement.


2. The measurand taxonomy — the single most important distinction#

A "±2 cm device" is not a meaningful specification, because error behaves completely differently depending on what is being measured. Falcon must specify accuracy per measurand.

Class Example How random error behaves Difficulty
Single point Coordinate of one surveyed target Full sensor noise applies Hard
Edge / corner Roof boundary, parapet line Limited by point spacing unless model-fitted Hard if picked from raw points; easy if fitted
Distance between two features Roof length, obstacle clearance Two point errors combine; pose error partly cancels over short baselines Moderate
Plane (offset and normal) Roof surface, pitch, azimuth Averages over N points — noise falls as 1/√N Easy
Area / volume Usable roof area Averages further Easy
Absolute coordinate in a world frame Georeferenced roof corner Adds full pose/registration error Hardest

This single table changes the programme. Random sensor noise averages away for planes and areas but not for points and edges. The consequence is developed in Section 6 and quantified in Section 9: roof pitch, azimuth, plane geometry and area are far easier to deliver accurately than individual point coordinates — and they are also what solar layout engineering mostly consumes.

Relative versus absolute accuracy#

These are different requirements with different costs:

  • Local / relative accuracy — the error in a dimension measured between two features within one scan. Needs no survey control. This is what rail lengths, roof spans, panel pitch and clearances depend on.
  • Absolute / georeferenced accuracy — the error in a coordinate expressed in a site or map frame. Requires surveyed control targets, or RTK GNSS, or both.

Almost all mounting-structure engineering needs the first. Demanding the second as a blanket product specification would force surveyed control targets onto every roof, which directly contradicts the product promise of minimal setup. Section 10 treats this tension as a product decision, not a technical detail.

Recommended specification form. Survey instruments are not specified as a single number; they are specified as a length-dependent pair, as in an EDM's ±(1 mm + 1.5 ppm). Falcon should adopt the same form:

accuracy = ±(a + b · L), where L is the separation between the two features being measured

This is honest about the physics, it is testable, and it stops a single headline number from being quoted out of context. Proposed values are in the tolerance document.


3. Error sources#

ID Source Scales with Reducible by
E1 Sensor range noise constant, or weakly with range averaging over points
E2 Sensor angular error linearly with range sensor choice
E3 Pose / trajectory error (SLAM drift) with path length loop closure, control points, RTK
E4 Calibration: boresight (angular) linearly with range calibration at representative range
E5 Calibration: lever arm (translation) constant careful metrology
E6 Time synchronisation × platform motion range × angular rate × offset hardware sync, deskewing
E7 Feature / target definition constant explicit geometric definitions
E8 Surface and incidence effects strongly with incidence angle and material operating procedure
E9 Reference (ground-truth) uncertainty constant survey discipline

E3 is normally dominant. E2, E4 and E6 are the sources most often ignored, and all three grow with range — which is why a device characterised at 2 m can disappoint at 12 m.


4. Stereo depth — a validated model and a decisive result#

4.1 The model#

For a calibrated stereo pair, depth is recovered from disparity, and depth precision follows:

            z²  ·  σ_d
   σ_z  =  ─────────────
              f  ·  b

where z is range (m), f the focal length (pixels), b the stereo baseline (m) and σ_d the disparity matching precision (pixels). The z² term is the whole story: stereo depth error grows with the square of distance.

4.2 Calibrating the model against published specifications#

Orbbec publishes spatial-precision figures for two Gemini 330-series cameras that share optics and resolution but differ in baseline (official specification — Gemini 335, Gemini 335L). Solving the model for σ_d at each published point:

Published point Baseline f · b Published σ_z Implied σ_d
Gemini 335 — ≤1.5 % at 2 m 50 mm 32.0 30 mm 0.240 px
Gemini 335L — ≤0.8 % at 2 m 95 mm 60.8 16 mm 0.243 px
Gemini 335L — ≤1.6 % at 4 m 95 mm 60.8 64 mm 0.243 px

Three independent published figures, spanning two baselines and two ranges, imply the same disparity precision to within 1 %. (Falcon analysis.)

This is a strong result. It means the simple model reproduces the manufacturer's own specifications, so it can be projected to other baselines and ranges with real confidence. Adopted value: σ_d = 0.24 px, with f = 640 px for a 1280-pixel-wide sensor at 90° horizontal field of view.

4.3 Projected stereo depth precision (1σ)#

Candidate rig 2 m 3 m 5 m 10 m 15 m 25 m
Gemini 335 — b = 50 mm 30 mm 67 mm 187 mm 750 mm 1 687 mm 4 687 mm
Gemini 335L — b = 95 mm 16 mm 36 mm 99 mm 395 mm 888 mm 2 467 mm
ZED 2i 2.1 mm — b = 120 mm 18 mm 40 mm 112 mm 446 mm 1 004 mm 2 789 mm
ZED 2i 4 mm — b = 120 mm 8 mm 19 mm 53 mm 211 mm 474 mm 1 317 mm

(Falcon analysis from the model in 4.1, calibrated in 4.2. Stereolabs separately publishes figures of this order for ZED-family cameras — for example a sub-5 % depth error at 12–15 m, which is 0.5–0.75 m. Manufacturers using learned depth estimation may beat 0.24 px on well-textured scenes; none of them can escape the z² term.)

4.4 The decisive conclusions#

Range at which each rig first reaches 20 mm precision:

Rig 20 mm horizon
Gemini 335 (50 mm baseline) 1.6 m
ZED 2i 2.1 mm (120 mm baseline) 2.1 m
Gemini 335L (95 mm baseline) 2.3 m
ZED 2i 4 mm (120 mm baseline) 3.1 m

Baseline that would be required to reach 20 mm at longer range:

Range Required baseline
5 m 0.47 m
10 m 1.87 m
15 m 4.22 m
25 m 11.7 m

Finding F-1 — Fixed-baseline stereo cannot deliver ±20 mm at rooftop standoff distances#

Reaching 20 mm precision at 10 m would require a stereo baseline of about 1.9 m. A handheld device is roughly 0.2 m across — an order of magnitude short. No choice of camera within the candidate set changes this, because the limit is geometric, not a question of sensor quality.

Passive stereo is therefore not a ranging sensor for Falcon's working distances. Its useful contributions are texture, colour, edges and semantics; short-range geometry within about 2–3 m; and visual-inertial odometry. It should be specified and tested for those roles, not scored on depth accuracy at 10 m.

Finding F-2 — Operator motion provides the baseline that the device cannot#

Structure-from-motion and multi-view stereo use the operator's walk as the baseline. Walking 2 m between viewpoints yields the ~1.9 m effective baseline that F-1 shows is needed at 10 m.

This is a genuinely different error regime from fixed-baseline stereo and it is currently absent from the Falcon documents. Photogrammetry from a moving camera is a credible route to roof geometry and deserves to be an explicit, separately evaluated R&D track — with its own weaknesses: it needs texture, it needs good pose estimates, it is compute-heavy, and it fails on uniform surfaces such as clean sheet metal.

4.5 A procurement consequence that follows immediately#

Comparing the candidate stereo cameras on the specifications that actually matter for a handheld device (official specification, sources as linked in the vendor register):

Gemini 335 Gemini 335L ZED 2i
Baseline 50 mm 95 mm 120 mm
Ideal range 0.26–3.0 m 0.25–6.0 m lens-dependent
Depth shutter Global Global Rolling
RGB shutter Rolling Global Rolling
Published precision ≤1.5 % @ 2 m ≤0.8 % @ 2 m, ≤1.6 % @ 4 m ~1 % @ 3 m class

Two points deserve attention, and neither currently appears in the vendor register:

  1. Rolling shutter is a defect in a handheld scanner. A rolling-shutter sensor exposes image rows sequentially, so rotating the device skews the image. The Gemini 335's depth sensors are global shutter but its RGB sensor is rolling shutter — which matters because RGB is what would be used for colourisation, feature tracking and any photogrammetry track (Finding F-2). The Gemini 335L has global shutter on both.
  2. The Gemini 335's ideal range of 0.26–3.0 m is below Falcon's working distances. The 335L's 0.25–6.0 m is a far better match, with roughly double the baseline.

Finding F-3 — The Gemini 335 is the wrong SKU in its own family for this application#

On baseline, ideal range and RGB shutter type, the Gemini 335L is better matched to handheld rooftop scanning than the Gemini 335 currently listed as the lead candidate. The register's existing warning that suffixes are not interchangeable is correct and this is a concrete instance of it. Confirm against the exact-SKU datasheet before acting.


5. LiDAR point geometry — the angular term is the one that bites#

A LiDAR point's error has a range component along the beam and a lateral component across it. The lateral component is R · tan(σ_θ) and therefore grows linearly with range.

Using published figures for two representative classes (official specification — Livox MID-360: range precision ≤2 cm at 10 m, angular precision <0.15° (1σ); Ouster OS0-class Rev 7 datasheets: range precision of order ±1–3 cm with angular sampling accuracy ±0.01°):

MID-360 class — σ_R = 20 mm, σ_θ = 0.15°#

Range Lateral 3D point Normal error at 0° incidence at 60° incidence
2 m 5 mm 21 mm 20 mm 11 mm
5 m 13 mm 27 mm 20 mm 15 mm
10 m 26 mm 42 mm 20 mm 25 mm
15 m 39 mm 59 mm 20 mm 35 mm
25 m 65 mm 95 mm 20 mm 58 mm

OS0 class — σ_R = 15 mm, σ_θ = 0.01°#

Range Lateral 3D point Normal error at 0° incidence at 60° incidence
2 m 0.3 mm 15 mm 15 mm 8 mm
5 m 0.9 mm 15 mm 15 mm 8 mm
10 m 1.7 mm 15 mm 15 mm 8 mm
15 m 2.6 mm 16 mm 15 mm 8 mm
25 m 4.4 mm 16 mm 15 mm 8 mm

Finding F-4 — For the MID-360 class, angular error exceeds range error beyond about 8 m#

At 10 m the lateral error (26 mm) is larger than the headline range precision (20 mm), and by 25 m it is three times larger. A sensor advertised as "±2 cm" delivers a 42 mm 3D point error at 10 m once its angular term is included.

The two sensor classes differ by more than an order of magnitude in angular performance. Any comparison that quotes only range precision will rank them wrongly. Angular precision must be a mandatory comparison field in the vendor register and the procurement matrix.

5.1 The mass and power counter-argument#

Better angular performance is not free. The wide-field-of-view Ouster class is substantially heavier and more power-hungry than the compact Livox class — of order 500 g against 265 g (official specification for MID-360 mass; Ouster mass to be confirmed per exact part number).

Finding F-5 — The current product targets and the stated vendor preference are in direct conflict#

The working targets are a device under 1 kg, a sensor under 300 g and system power under 15 W. A ~500 g LiDAR consumes the entire sensor mass budget and more, before any camera, battery, compute, enclosure or display.

This is a real trade that must be decided consciously rather than discovered during industrial design:

  • relax the mass target — accept a heavier device, perhaps shoulder- or pole-mounted;
  • split the roles — use the higher-grade sensor as a characterisation and reference instrument during R&D, and a compact sensor in the product;
  • re-derive the requirement — establish from the tolerance analysis whether the compact class is in fact sufficient for the measurands that matter (Section 9 suggests it is, for Tier B and Tier C).

The third option is the most likely to be correct, and it is the one the evidence supports. It should be tested in V1-00 rather than assumed.

5.2 Point spacing is sampling, not error#

Angular resolution determines how finely a surface is sampled. At 10 m:

Angular resolution 2 m 5 m 10 m 15 m 25 m
0.18° 6 mm 16 mm 31 mm 47 mm 79 mm
0.35° 12 mm 31 mm 61 mm 92 mm 153 mm
0.70° 24 mm 61 mm 122 mm 183 mm 305 mm
1.40° 49 mm 122 mm 244 mm 367 mm 611 mm

Two consequences:

  • A 0.7° channel spacing gives 122 mm point spacing at 10 m. A 100 mm obstacle at 10 m may fall between beams. Obstacle detection is limited by sampling, not by ranging precision — which is why operator motion matters: sweeping the device fills the gaps between channels.
  • The 100 mm completeness grid already proposed in V1-00 is well matched to point spacing at 10 m. That choice is quantitatively justified, and this analysis supports keeping it.

6. Plane fitting — where the physics works in Falcon's favour#

Fitting a plane to N points averages down random error:

   σ_plane_offset  ≈  σ_normal / √N
Points on the patch Plane offset uncertainty from 25 mm normal noise
10 7.9 mm
100 2.5 mm
1 000 0.8 mm
10 000 0.25 mm

A LiDAR producing 200 000 points/s will put thousands of points on a roof patch in a fraction of a second. Random noise is therefore not the limiting factor for plane measurements at all.

Plane orientation behaves the same way. For a patch of given extent with N points and 25 mm normal noise:

Patch extent N = 100 N = 1 000
1 m ~0.29° ~0.09°
3 m ~0.10° ~0.03°
5 m ~0.06° ~0.02°

Finding F-6 — Roof pitch and azimuth are comfortably achievable, with a large margin#

A 3 m roof patch with a thousand points yields plane-normal uncertainty of roughly 0.03° from random noise — more than an order of magnitude inside the ±0.5° that structural prefabrication needs.

Pitch, azimuth, plane geometry and roof area are the easy measurands, and they are exactly what mounting-structure engineering consumes most. The residual risk for these measurands is systematic error — calibration bias, pose tilt error, incidence-dependent bias — not noise. V1-00 should therefore test pitch and azimuth for bias and repeatability, not for noise.

6.1 Edges must be fitted, never picked#

At 10 m with 0.7° spacing, picking the outermost point of a roof edge cannot locate it better than about half the point spacing — roughly 60 mm — and the outermost point is also the one most contaminated by mixed returns at the edge.

Intersecting two fitted planes recovers the same edge far more accurately, because each plane is heavily over-determined.

Finding F-7 — Roof boundaries, ridges and parapet lines must be derived by plane intersection#

This is a method requirement, not a preference. V1-00 already requires that each edge comparison state its geometric definition; this analysis supplies the reason and the quantitative penalty for getting it wrong. The processing specification must fit-and-intersect, and the reference survey must define the same physical feature.


7. Time synchronisation — the requirement nobody has derived#

Timing error becomes geometric error through platform motion. Two mechanisms, and the rotational one is much the larger.

Translation: error = v · Δt

Walking speed Δt = 1 ms 5 ms 10 ms 50 ms
0.5 m/s 0.5 mm 2.5 mm 5 mm 25 mm
1.0 m/s 1.0 mm 5 mm 10 mm 50 mm
1.5 m/s 1.5 mm 7.5 mm 15 mm 75 mm

Rotation: error = R · ω · Δt

Angular rate Range Δt = 1 ms 5 ms 10 ms 50 ms
15 °/s 10 m 2.6 mm 13 mm 26 mm 131 mm
30 °/s 10 m 5.2 mm 26 mm 52 mm 262 mm
90 °/s 10 m 15.7 mm 79 mm 157 mm 785 mm
30 °/s 15 m 7.9 mm 39 mm 79 mm 393 mm

Inverting this to a requirement — the synchronisation offset that keeps timing-induced error at or below 5 mm at 10 m range:

Angular rate Maximum permissible Δt
15 °/s 1.9 ms
30 °/s 0.95 ms
90 °/s 0.32 ms

Finding F-8 — Sub-millisecond synchronisation is a hard requirement, derived not assumed#

At a natural handheld panning rate of 30 °/s, holding timing-induced error to 5 mm at 10 m requires synchronisation better than 1 ms. During turns, where rates reach 90 °/s, it requires better than 0.35 ms.

Software timestamping on a general-purpose host, subject to USB buffering and scheduler jitter, routinely exceeds 10 ms. Hardware synchronisation — trigger I/O or PTP — is therefore a requirement for the product, not an optional nicety. Candidate sensors that cannot expose hardware timestamps are disqualified for the product even if they are usable for early algorithm work.

This also converts a vendor marketing phrase into a testable number. V1-00 can now state what measured synchronisation performance is sufficient, rather than merely requiring that it be measured.

7.1 Motion compensation is fundamental, not an optimisation#

Within a single 100 ms frame of a 10 Hz LiDAR, the device keeps moving:

Angular rate Sweep during one frame Apparent smear at 10 m
15 °/s 1.5° 262 mm
30 °/s 3.0° 524 mm
90 °/s 9.0° 1 571 mm

Finding F-9 — Per-point deskewing is mandatory#

Treating a LiDAR frame as a single instantaneous observation introduces errors of hundreds of millimetres at ordinary handheld motion rates — one to two orders of magnitude beyond the target tolerance.

Therefore: per-point timestamps and a high-rate IMU are mandatory data requirements, and deskewing is a mandatory processing stage. A sensor that does not expose per-point timestamps cannot be deskewed correctly by Falcon's own pipeline. This must become a hard filter in the procurement matrix's data-access table.


8. Calibration — why calibration range matters as much as calibration quality#

Extrinsic calibration between LiDAR and camera has an angular part (boresight) and a translational part (lever arm). The angular part is amplified by range; the translational part is not.

Lateral error contributed by boresight residual:

Boresight residual 2 m 5 m 10 m 15 m 25 m
0.05° 1.7 mm 4.4 mm 8.7 mm 13 mm 22 mm
0.10° 3.5 mm 8.7 mm 17 mm 26 mm 44 mm
0.20° 7.0 mm 17 mm 35 mm 52 mm 87 mm
0.50° 17 mm 44 mm 87 mm 131 mm 218 mm

Finding F-10 — Calibrating at 2 m and operating at 15 m amplifies angular residual 7.5×#

A target-based calibration performed at a comfortable indoor distance of about 2 m, with a typical 0.2° residual, contributes only 7 mm at the calibration distance but 35 mm at 10 m and 52 mm at 15 m — on its own exceeding the target tolerance.

Two consequences:

  1. Boresight accuracy must be held to roughly 0.05° for the calibration contribution to stay under about 10 mm at 10 m. This is a demanding but stated target, and V1-00 must report the achieved residual against it.
  2. Calibration must be verified at operating range, not only at calibration-target range. V1-00's existing instruction to use "adequate range variation" is correct; this analysis supplies the number and the reason. Verification observations at 8–15 m should be mandatory, and the lever arm and boresight errors must be reported separately, because they behave differently with range.

9. Combined budget and feasibility verdicts#

Combining terms in quadrature for a handheld scan with loop closure and no survey control, at 10 m range (Falcon analysis — illustrative composition, to be replaced by measured values from V1-00):

Measurand Dominant terms Expected achievable (1σ) Tier target Verdict
Roof plane pitch calibration bias, pose tilt 0.05–0.2° ±0.5° Achievable, large margin
Roof plane azimuth pose heading, control 0.1–0.5° ±1–2° Achievable
Plane offset / flatness systematic bias only 2–10 mm ±25 mm Achievable
Roof area averaged boundary error 0.3–1 % ±2 % Achievable
Local distance, L ≤ 10 m E1, E2, partial pose 15–40 mm ±(10 mm + 1 mm/m) Marginal — the key V1 question
Obstacle height E1, E2, pose 20–50 mm ±50 mm Marginal, probably achievable
Edge / parapet line (fitted) plane fit, definition 10–30 mm ±50 mm Achievable if fitted, not if picked
Single point, absolute, no control E3 pose drift 50–500 mm — Not achievable
Single point, absolute, with control control residual 10–30 mm ±50 mm Achievable with control targets
Prefabrication dimension all terms 15–40 mm ±15 mm Not achievable optically — see F-12
Far-field shading context at 20–50 m E2, E3 100–500 mm ±500 mm Achievable, different sensor regime

Independent corroboration: published comparisons of mature commercial handheld SLAM scanners against terrestrial laser scanners report accuracies of roughly 10–30 mm, with one assessment finding about 5 mm indoors but 10–60 mm outdoors, while tripod-mounted terrestrial scanners achieve 3–6 mm at 10 m (independent test — see Section 13).

Finding F-11 — The ±2 cm target sits at or beyond the state of the art for this form factor#

Mature handheld scanning products from companies with far greater R&D investment achieve 10–30 mm, and degrade to 10–60 mm outdoors — which is Falcon's entire operating environment.

This does not kill the project. It means:

  • ±2 cm must not be carried forward as a blanket product specification. Doing so would commit Sunrack publicly to beating the industry's best, outdoors, at lower cost.
  • Tiered, measurand-specific, length-dependent tolerances are the correct formulation — and the commercially valuable tiers are achievable.
  • The programme's realistic ambition is to be competitive on accuracy and superior on solar-specific workflow, not to win an accuracy contest.

Finding F-12 — The measurement that most needs tight tolerance may not be optically measurable#

The tightest genuine requirement in mounting-structure work is the position of purlins and rafters, because rails are pre-cut and clamps must land on structural members. On a sheet-metal roof those members are underneath the sheet and invisible to any optical sensor.

No improvement in scanner accuracy addresses this. It needs a different method — inference from visible fastener lines or sheet profile, a magnetic or probe-based locator, measurement from below, or acceptance that this dimension stays a manual task.

This is the most important finding in this document for product scope. It should be settled before the architecture is frozen, because it determines whether Falcon is a complete survey solution or a partial one, and that changes the product claim and the customer workflow.


10. The product tension this analysis exposes#

Product promise Technical reality Resolution
"Minimal setup" Absolute accuracy needs surveyed control targets Specify local/relative accuracy as the primary requirement; treat georeferencing as an optional mode
"±2 cm" At or beyond state of the art outdoors (F-11) Tiered tolerances per measurand (F-6, F-9)
"One-minute scan" Longer scans drift more; shorter scans cover less Specify scan time against roof area and a closure requirement
"<1 kg, <300 g sensor" Best-performing LiDAR class is ~500 g (F-5) Decide the trade explicitly after V1-00
"Stereo + LiDAR fusion" Stereo contributes no useful ranging beyond ~3 m (F-1) Re-scope stereo to texture, edges, semantics and odometry

The central recommendation: specify Falcon as a relative-accuracy instrument with an optional georeferenced mode, with tolerances stated per measurand in the ±(a + b·L) form. This is achievable, honest, testable, and it preserves the minimal-setup product promise for the majority of use cases.


11. What this analysis changes in the programme#

Document Required change Finding
Product requirements Replace the single ±2 cm target with tiered, measurand-specific tolerances F-6, F-11
Vendor register Add angular precision, shutter type and per-point timestamp support as mandatory fields F-3, F-4, F-9
Vendor register Re-scope stereo evaluation away from depth accuracy at range F-1
Procurement matrix Make hardware sync and per-point timestamps hard filters, not scored attributes F-8, F-9
V1-00 specification Add quantitative thresholds; test pitch for bias not noise; verify calibration at operating range F-6, F-8, F-10
V1-00 specification Add a photogrammetry/structure-from-motion processing path to the comparison F-2
Prototype V1 plan Add a purlin-locatability investigation before architecture freeze F-12
Architecture Make deskewing and time-base definition explicit, specified stages F-8, F-9
Decision log Record the mass-versus-performance trade as an open decision F-5

12. How to falsify this analysis#

This document is a prediction. It should be checked, and these are the measurements that would overturn it:

Claim Falsified if V1-00 measures
F-1: stereo gives no useful ranging beyond ~3 m Stereo depth RMSE ≤ 50 mm at 10 m on roof surfaces
F-4: angular error dominates beyond ~8 m Lateral scatter at 15 m materially below R · tan(σ_θ)
F-6: plane normals reach ~0.03° Plane-normal repeatability worse than 0.3° on a surveyed patch
F-8: sub-millisecond sync needed No measurable geometric degradation at 10 ms offset during 30 °/s motion
F-11: ±2 cm is beyond reach outdoors 3D checkpoint RMSE ≤ 20 mm outdoors with adequate sample size
σ_d = 0.24 px model Measured stereo precision departing from the z² law by more than ~30 %

If a measurement contradicts this analysis, the measurement wins — provided it satisfies V1-00's metrology and leakage rules. Record the contradiction and revise this document with a new version number.


13. Assumptions, limitations and sources#

Assumptions#

  1. Random errors are independent and combine in quadrature. Real systems have correlated error; this budget is therefore optimistic for systematic terms.
  2. Stereo disparity precision is treated as range-independent at 0.24 px. In practice it degrades with poor texture, low contrast and bright sunlight, so the stereo table is a best case.
  3. LiDAR range precision is treated as constant with range; published figures are usually quoted at one distance and one reflectivity.
  4. Plane-fit averaging assumes independent noise and adequate point distribution. Systematic bias does not average away.
  5. Pose-error ranges are drawn from published literature on comparable systems, not from Falcon measurement.
  6. All sensor inputs are manufacturer-published figures for the model named, at the manufacturer's stated test conditions. Exact SKU, firmware and operating mode must be confirmed per the vendor register's rules before any of these numbers is used in a procurement decision.

Limitations#

This analysis covers geometric error only. It does not address data completeness in occluded regions, behaviour on wet or highly specular surfaces, thermal drift of calibration, or failure modes in direct sun — all of which are in V1-00's scope and none of which is predictable analytically with useful confidence.

Sources#

Sensor inputs are the manufacturer pages already catalogued in the Vendor Evaluation Register and Procurement Matrix Guidance; the register is the single place where source URLs, revisions and review dates are maintained.

Independent accuracy context for handheld SLAM scanning:

  • A comparison of terrestrial laser scanning and handheld mobile mapping for built heritage, reporting centimetre-level accuracy for both and quantifying the detail trade-off — ISPRS Archives / d-nb.info.
  • An assessment of SLAM-scanner accuracy for indoor and outdoor surveying, reporting about 5 mm indoors against 10–60 mm outdoors and documenting georeferencing drift — ResearchGate record.
  • A method-selection comparison giving 3–6 mm at 10 m for terrestrial scanners against 10–30 mm for handheld SLAM — icelabz.co.uk.

The arithmetic in this document is reproducible from the formulae in Sections 4, 5, 6, 7 and 8; the script used to generate every table is retained with the project's analysis records.

Reference uncertainty cross-check#

V1-00 requires the reference measurement's expanded uncertainty to be no more than one third of the tolerance under evaluation — for a 20 mm tolerance, U95 ≤ 6.7 mm. A conventional total station with 1″ angular performance and ±(1 mm + 1.5 ppm) EDM, combined with 1 mm centring and 1.5 mm target definition, gives a combined standard uncertainty of about 2.1 mm and U95 ≈ 4.2 mm at 10–50 m (Falcon analysis).

That satisfies the rule — but note what dominates it. The instrument's angular and distance terms contribute well under 1.1 mm; centring and target-centre definition contribute most of the budget. The surveyor's target discipline therefore matters more than the instrument's brochure specification, which reinforces V1-00 Section 7.2's insistence on recording centring method, prism constant and target-centre offsets.

Source: docs/02-architecture/ERROR_BUDGET_AND_FEASIBILITY.md